Description
Internet procedure, executed from a Web browser, that tests whether OECGI/OECGI2 is running on a Web server.
Syntax
Inet_Test_Connect(Request)
Note: Request is any text after the string INET_TEST_CONNECT?
Parameters
The Inet_Test_Connect function has the following parameter:
Parameters | Description |
---|---|
Request | [in] HTTP-request. |
return | [out] Incoming request as an HTML script. |
Returns
Incoming request as an HTML script, displayed in the Web browser.
See also
Inet_Msg(), Inet_QueryParam(), Inet_Repos(), Inet_Rlist(), Inet_Security(), Inet_Trace()
Example
To test whether OECGI/OECGI2 is properly installed, use the IP address 127.0.0.1 (the localhost loopback address), and enter the following URL in the server's Web browser:
http://127.0.0.1/cgi-bin/oecgi.exe/Inet_Test_Connect
If OECGI/OECGI2 is properly installed, the following HTML will be returned:
<!DOCTYPE html> <html> <head> <title> OpenInsight Inet_Test_Connect Response </title> </head> <body > <H1>Congratulations!</h1> <br>If you can read this, you have successfully connected to OpenInsight </body> </html>